Fluke 393FC True RMS Clamp Meter with Iflex

Product Details
After-sales Service: Yes
Warranty: 1 Year Warranty
Brand: Fluke
Still deciding? Get samples of US$ 489/Set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (7)
  • Fluke 393FC True RMS Clamp Meter with Iflex
  • Fluke 393FC True RMS Clamp Meter with Iflex
  • Fluke 393FC True RMS Clamp Meter with Iflex
  • Fluke 393FC True RMS Clamp Meter with Iflex
  • Fluke 393FC True RMS Clamp Meter with Iflex
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
393FC
Customized
Non-Customized
Certification
CE, ISO, RoHS
Display
Digital
Stucture
Transformer
Voltage
High Voltage
Brand Name
Fluke
Model
393FC
Maximum Voltage
1500 V DC
AC/DC Current
999.9 a
Flexible Current Probe
2500 a
Resistancetrange
600 Ω, 6000 Ω, 60 KΩ
Temperaturetoperating
14 to 122°f (-10 to 50°c)
Transport Package
UPS/DHL/FedEx
Specification
33*21*12cm
Trademark
FLUKE
Origin
China
HS Code
9028309000

Packaging & Delivery

Package Size
35.00cm * 20.00cm * 18.00cm
Package Gross Weight
2.300kg

Product Description

Ideal for technicians who work in dc environments up to 1500 V, this true-rms clamp meter features a slim jaw to allow access to crowded combiner boxes and is IP54 rated for work outdoors. In addition, this meter features a flexible current probe that extends AC current measurements up to 2500 A.

Features

  • IP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systems
  • DC power measurement, showing readings in kVA
  • Audio polarity indicator helps prevent accidental miswires
  • Visual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via software
  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
  • MC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 V
  • View voltage and current simultaneously with the meter's dual display
Fluke 393FC True RMS Clamp Meter with Iflex

Fluke 393 FC - CAT III 1500V TRMS Wireless Clamp Meter with iFlex (2500 A AC/999.9 A DC)

 
  • Maximum AC current = 2500 A
  • Maximum DC current = 999.9 A
  • Maximum AC voltage = 1000 V
  • Maximum DC voltage = 1500 V
  • True RMS = yes
The 393 FC CAT III 1500 V True-RMS Clamp Meter with iFlex is designed for technicians who work in high voltage DC environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V DC, 1000 V AC, and up to 999.9 A DC or AC through the clamp jaw. The included iFlex flexible current probe extended AC current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind and are also rated to CAT III 1500 V DC.
Product Parameters
Maximum Voltage Between Any Terminal and Earth Ground 1000 V AC
1500 V DC
Electrical Specifications Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
AC Current: Jaw Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)

Crest factor (50/60 Hz):
2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2% for C.F. >2
AC Current: Flexible Current Probe Range: 999.9 A; 2500 A
Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)
Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):
2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2% for C.F. >2
Position Sensitivity Distance from optimum:
A
B
C

i2500-18 Flex:
1.4" (35.6 mm)
2" (50.8 mm)
2.5" (63.5 mm)

Error:
±0.5%
±1%
±2%
DC Current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
AC Voltage Range: 600 V; 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 to 500 Hz)
DC Voltage Range: 600 V; 1500
Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV DC Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps Frequency: Jaw Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Voltage Frequency Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 20 Hz, ≥5 V
20 to 100 Hz, ≥5 V
100 to 500 Hz, ≥10 V
DC Power Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)
Resolution: 0.1 kVA, 1 kVA
Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
Resistance Range: 600 Ω, 6000 Ω, 60 kΩ
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance Range: 100 μF, 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level: 5 A
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity Non-condensing <50°F (10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C)
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.07' (12,000 m)
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety General: IEC 61010-1, Pollution Degree 2

Measurement:
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range: 2400 to 2483.5 MHz
Output power: <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
Automatic Power Off 20 minutes
Display Dual display with backlight
Batteries Two AA IEC LR6 alkaline
Dimensions Size: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm)
Jaw opening: 1.33" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)
Flexible current probe cable length (head to electronics connector): 0.07" (1.8 m)
Weight (With Batteries) 1.14 lbs (520 g)
   
Fluke 393FC True RMS Clamp Meter with Iflex
Fluke 393FC True RMS Clamp Meter with Iflex
Fluke 393FC True RMS Clamp Meter with Iflex
 
Fluke 393FC True RMS Clamp Meter with Iflex
Fluke 393FC True RMS Clamp Meter with Iflex
Fluke 393FC True RMS Clamp Meter with Iflex

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier