After-sales Service: | Yes |
---|---|
Warranty: | 1year |
Customized: | Non-Customized |
Screen Size: | 4.3-Inch |
SD Card Memory Size: | 32G |
Sampling Frequency: | 10.24 kHz at 50/60 Hz, Synchronized to Mains Frequ |
Suppliers with verified business licenses
Fluke 1736/EUS Three-Phase Power Logger with Fluke Connect Compatibility and Flexible Current Probes
The Fluke 1736 Three-Phase Power Logger is designed to give users the information they need to make crucial power qualiy and energy decisions as efficently and quickly as possible. Fluke has paired the 1736 with its Fluke Connect® mobile app and desktop software to give users immediate access to critical information anywhere. Out of the box, the 1736 is capable of automatically capturing and storing more than 500 PQ paramters.
Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. Quickly and easily chart and graph measurements with the included Fluke Energy Analyze Plus software package.
The four current probes are connected separately; the instrument automatically detects and scales the probes. The thin current probes are designed to easily get through tight conductor spacing and are easily set to 150 or 1500 A for high accuracy in nearly any application. An innovative tangle-free flat voltage lead makes connection simple and reliable and the instrument's intelligent 'Verify Connection' feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement leads. The detachable power supply can be conveniently and safely powered directly from the measured circuit-no more searching for power outlets or having to run multiple extension cords to the logging location.
Capturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke Energy Analyze Plus software makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you'll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings
Specifications | ||||
Accuracy | ||||
Parameter | Range | Max. resolution | Intrinsic accuracy at reference conditions (% of reading + % of full scale) |
|
Voltage | 1000 V | 0.1 V | ± (0.2% + 0.01%) | |
Current | i17xx-flex 1500 12" |
150 A 1500 A |
0.1 A 1 A |
± (1% + 0.02%) ± (1% + 0.02%) |
i17xx-flex 3000 24 |
300 A 3000 A |
1 A 10 A |
± (1% + 0.03%) ± (1% + 0.03%) |
|
i17xx-flex 6000 36" |
600 A 6000 A |
1 A 10 A |
± (1.5 % + 0.03%) ± (1.5 % + 0.03%) |
|
i40s-EL clamp | 4 A 40 A |
1 mA 10 m A |
± (0.7% + 0.02 %) ± (0.7% + 0.02 %) |
|
Frequency | 42.5 Hz to 69 Hz | 0.01 H z | ± (0.1%) | |
Aux input | ± 10 V dc | 0.1 mV | ± (0.2% + 0.02%) | |
Voltage min/max | 1000 V | 0.1 V | ± (1% + 0.1%) | |
Current min/max | defined by accessory |
defined by accessory |
± (5% + 0.2%) | |
THD on voltage | 1000% | 0.1% | ± 0.5 | |
THD on current | 1000% | 0.1% | ± 0.5 | |
Voltage harmonics 2nd ...50th | 1000 V | 0.1 V | ≥ 10 V: ± 5% of reading < 10 V: ± 0.5V |
|
Current harmonics 2nd ... 50th |
defined by accessory |
defined by accessory |
≥ 3% of current range: ± 5% of reading < 3% of current range: ± 0.15% of range |
|
Unbalance | 100% | 0.1% | ± 0.2 |
Intrinsic uncertainty ± (% of reading + % of range)1 | |||||
Parameter | Influence quantity |
iFlex1500 -12 150A/1500A |
iFlex3000-24 300A/3000A |
iFlex6000-36 600/6000A |
i40s-EL 4A/40A |
Active Power PActive Energy Ea | PF = 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent Power S Apparent Energy Eap | 0 = PF = 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Reactive Power Q Reactive Energy Er | 0 = PF = 1 | 2.5 % of measured apparent power | |||
Power Factor PF Displacement Power FactorDPF/cosφ | - | ± 0.025 | |||
Additional uncertainty in % of range1 | V P-N > 250 V | 0.015% | 0.0225% | 0.0225 % | 0.015% |
Electrical specifications | |
Power supply | |
Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit |
100 V to 240 V using standard power cord (IEC 60320 C7) | |
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |
Efficiency | ≥ 68.2 % (in accordance with energy efficiency regulations) |
Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input |
Mains power frequency | 50/60 Hz ± 15 % |
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode |
Charging time | < 6 hours |
Data acquisition | |
Resolution | 16-bit synchronous sampling |
Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |
Circuit types | 1-?, 1-? IT, split phase, 3-? delta, 3-? wye, 3-? wye IT, 3-? wye balanced, 3-? Aron/Blondel (2-element delta), 3-? delta open leg, currents only (load studies) |
Data storage | Internal flash memory (not user replaceable) |
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events 1 |
Basic interval | |
Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms |
Demand Interval (Energy Meter Mode) | |
Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
Power quality measurements | |
Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD |
Averaging interval | 10 min |
Individual harmonics | 2nd ...50th harmonic |
Total harmonic distortion | Calculated on 50 harmonics |
Events | Voltage: dips, swells, interruptions, current: inrush current |
Triggered recordings | Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30) Waveform of voltage and current |
Electrical specifications cont. | |
Standards Compliance | |
Harmonics | IEC 61000-4-7: Class 1 IEEE 519 (short time harmonics) |
Power quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) |
Power | IEEE 1459 |
Power quality compliance | EN50160 (for measured parameters) |
Interfaces | |
USB-A | File transfer via USB flash drive, firmware updates, max. supply current: 120 mA |
WiFi | File transfer and remote control via direct connection or WiFi infrastructure |
Bluetooth | Read auxiliary measurement data from Fluke Connect ® 3000 series modules (requires 1738, or 1736 upgrade option) |
USB-mini | Data download device to PC |
Voltage inputs | |
Number of inputs | 4 (3 phases and neutral) |
Maximum input voltage | 1000 Vrms, CF 1.7 |
Input impedance | 10 MΩ |
Bandwidth | 42.5 Hz - 3.5 kHz |
Scaling | 1:1 and variable |
Measurement category | 1000 V CAT III/600 V CAT IV |
Current inputs | |
Number of inputs | 4, mode selected automatically for attached sensor |
Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12" |
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24" | |
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36" | |
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
Bandwidth | 42.5 Hz - 3.5 kHz |
Scaling | 1:1 and variable |
Auxiliary inputs | |
Number of inputs | 2 |
Input range | 0 to ± 10 V dc, 1 reading/s |
Scale factor | Format: mx + b (gain and offset) user configurable |
Displayed units | User configurable (7 characters, for example, °C, psi, or m/s) |
Wireless connection | |
Number of inputs | 2 |
Supported modules | Fluke Connect ® 3000 series |
Acquisition | 1 reading/s |
Environmental specifications | |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) |
Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH |
Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
Storage altitude | 12,000 m |
Enclosure | IP50 in accordance with EN60529 |
Vibration | MIL-T-28800E, Type 3, Class III, Style B |
Safety | IEC 61010-1 IEC Mains Input:Overvoltage Category II, Pollution Degree 2 Voltage Terminals:Overvoltage Category IV, Pollution Degree 2 |
IEC 61010-2-031:CAT IV 600 V / CAT III 1000 V | |
Electromagnetic compatibility (EMC) | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
Korea (KCC):Class A Equipment (industrial broadcasting and communication equipment) |
|
USA (FCC):47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
|
Temperature coefficient | 0.1 x accuracy specification/°C |
General specifications | |
Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |
Warranty | Instrument and power supply: Two-years (battery not included) Accessories: one-year Calibration cycle: two-years |
Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) |
Weight | Instrument: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb) |
Tamper protection | Kensington lock slot |
i17xx-flex 1500 12" Flexible Current Probe specifications | |
Measuring range | 1 to 150 A ac/10 to 1500 A ac |
Nondestructive current | 100 kA (50/60 Hz) |
Intrinsic error at reference condition* | ± 0.7 % of reading |
Accuracy 173x + iFlex | ± (1 % of reading + 0.02 % of range) |
Temperature coefficient over operating temperature range | 0.05 % of reading/°C 0.09 % of reading/°F |
Working voltage | 1000 V CAT III, 600 V CAT IV |
Probe cable length | 305 mm (12 in) |
Probe cable diameter | 7.5 mm (0.3 in) |
Minimum bending radius | 38 mm (1.5 in) |
Output cable length | 2 m (6.6 ft) |
Weight | 115 g |
Probe cable material | TPR |
Coupling material | POM + ABS/PC |
Output cable | TPR/PVC |
Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) |
Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) |
Relative humidity, operating | 15 % to 85 % non-condensing |
IP rating | IEC 60529:IP50 |
Warranty | One-year |
Model features | ||||||
1736 Power Logger | 1738 Power Logger | |||||
FLUKE-1736/B | FLUKE-1736/EUS | FLUKE-1738/B | FLUKE-1738/EUS | |||
Model | Power logger basic version | Power logger (EU and US) | Power logger advanced version | Power logger advance version (EU and US) | ||
Functions | ||||||
PQ Health (EN50160 analysis) | Opt. | Opt. | • | • | ||
IEEE 519 reporting | Opt. | Opt. | Opt. | Opt. | ||
Fluke Connect ® module support (up to 2 modules**) |
Opt. | Opt. | • | • | ||
Recording | ||||||
Trend | • | • | • | • | ||
Waveform Snapshots + RMS profile | Opt. | Opt. | • | • | ||
Communication | ||||||
USB (mini B) | • | • | • | • | ||
WiFi download of instrument data | • | • | • | • | ||
WiFi download via WiFi access point (requires registration)** | Opt. | Opt. | Opt. | Opt. | ||
Included Accessories | ||||||
WiFi only adapter** | - | • | - | - | ||
WiFi and BLE adapter** | Opt. | Opt. | Opt. | • | ||
USB flash drive (4GB) | • | • | • | • | ||
USB Cable | • | • | • | • | ||
3PHVL-173 Flat Cable | • | • | • | • | ||
1x red, 1x black 0.1m cable | • | • | • | • | ||
1x red, 1x black 1.5m lead | • | • | • | • | ||
Alligator clips | 4 | 4 | 4 | 4 | ||
C173x Soft Case | • | • | • | • | ||
Color Coding set | • | • | • | • | ||
173x-Hanger kit | Opt. | Opt. | • | • | ||
MP1-Magnet Probe | Opt. | Opt. | 4 | 4 | ||
i173X-flex1500 12" | Opt. | 4 | Opt. | 4 | ||
Line cord | EU, UK, US, AU, BR |
EU, US, UK | EU, UK, US, AU, BR |
EU, US, UK | ||
Compatible Optional Accessories | ||||||
173X- AUX analog adapter | • | • | • | • | ||
i17XX-flex1500 12" Current Probe | • | • | • | • | ||
i17XX-flex3000 24" Current Probe | • | • | • | • | ||
i17XX-flex6000 36" Current Probe | • | • | • | • | ||
i40s-EL Current Clamp | • | • | • | • | ||
IEEE 519 reporting opt | • | • | • | • | ||
1736 to 1738 upgrade (1736/UPGRADE) |
• | • | - | - |
Power Measurement/Power Loggers Template |
|
---|---|
Input(power loggers) | Single Phase, Three Phase |
Type(Power loggers) | Digital, Portable Hand Held |
Maximum Current AC | 1500 A |
Maximum Voltage AC | 1000 V |
True RMS | Yes |
Power Quality | Yes |
Current Input Channels | 4 |
Voltage Input Channels | 4 |
Measurement Frequency | 50 Hz, 60 Hz |
Display (Energy Management) | Digital, Graphical |
Transient Capture | No |
Displays Waveform | Yes |
Energy | Yes |
Phasor Diagrams | No |
Power Factor (Power Quality) | Yes |
Harmonics | Yes |
Total Harmonic Distortion | Yes |
Current Clamps Included | Yes |
Blue Tooth Compatable | Yes |
CAT Rating | IV |
CAT Voltage Rating (V) | 600V |
Test Equipment General Attributes |
|
Warranty | 2 YEARS |
Interfaces I/O | Bluetooth, Wifi, USB |
Storage | Internal Memory |
IP Rating | IP50 |
Product Weight | 3 LBS |
Product Height | 9.75 IN |
Product Length | 15.50 IN |
Product Width | 11.50 IN |
Data Logging | Yes |
Calibration Included | None |
Power Supply Voltage | 120V/220V Universal |
Country of Origin | Romania |
Shipping Height | 9.75 IN |
Shipping Length | 15.50 IN |
Shipping Width | 11.50 IN |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.
Suppliers with verified business licenses