Installation: | Portable |
---|---|
Display Mode: | Digital |
Accuracy: | ±0.025% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Digital Multi Meter with PC Interface
Hioki DT4200 Series Basic Comparison | |||||||||
Model | DT4281 | DT4282 | DT4252 | DT4253 | DT4254 | DT4255 | DT4256 | DT4221 | DT4222 |
Basic Characteristics | |||||||||
True RMS | Yes | Yes | Yes | ||||||
DCV basic accuracy | ±0.025 %rdg. ±2 dgt. | ±0.3 %rdg. ±5 dgt. | ±0.3 %rdg. ±3 dgt. | ±0.5 %rdg. ±5 dgt. | |||||
Measurement items (Typical ranges are indicated; may not reflect maximum or minimum measurable signal) | |||||||||
DC voltage | 60 mV to 1000 V | 600 mV to 1000 V | 600 mV to 1500 V | 600 mV to 1000 V | 600 mV to 600 V | ||||
AC voltage | 60 mV to 1000 V | 6 V to 1000 V | 6 V to 600 V | ||||||
DCV + ACV | 6 V to 1000 V | n/a | n/a | ||||||
DCA current | 600 μA to 600 mA | 600 μA to 10 A | 6 A to 10 A | 60 μA to 60 mA | n/a | 60 mA to 10 A | n/a | ||
ACA current | 600 μA to 600 mA | 600 μA to 10 A | 6 A to 10 A | n/a | 600 mA to 10 A | n/a | |||
AC clamp | 10 A to 1000 A | n/a | n/a | 10 A to 1000 A | n/a | 10 A to 1000 A | 10 A to 1000 A | n/a | |
Resistance | 60 Ω to 600 MΩ | 600 Ω to 60 MΩ | n/a | 600 Ω to 60 MΩ | n/a | 600 Ω to 60 MΩ | |||
Temperature | -40°C to 800°C | n/a | -40°C to 400°C | n/a | n/a | ||||
Capacitance | 1 nF to 100 mF | 1 μF to 10 mF | n/a | 1 μF to 10 mF | n/a | 1 μF to 10 mF | |||
Frequency | 99 Hz to 500 kHz | 99 Hz to 99 kHz | 99 Hz to 9.9 kHz | ||||||
Continuity check | Yes | Yes | n/a | Yes | Yes | ||||
Diode check | Yes | Yes | n/a | Yes | n/a | Yes | |||
Conductance | n/a | Yes | n/a | n/a | |||||
Voltage detection | n/a | n/a | Yes | Yes | n/a | ||||
Additional Functions | |||||||||
AUTO AC/DCV | n/a | n/a | Yes | Yes | n/a | ||||
Peak measurement | DC/AC | n/a | n/a | ||||||
Low-pass filter | Analog filter Cut-off : 630 Hz |
Digital filter Pass-band : 100Hz/500Hz |
Digital filter Pass-band : 100Hz/500Hz |
||||||
Display update setting | Yes | n/a | n/a | ||||||
Hold display value | AUTO / MANUAL | AUTO / MANUAL | MANUAL | ||||||
Max/Min value display | Yes | Yes | n/a | ||||||
Relative display | Yes | Yes | Yes | ||||||
Decibel conversion | Yes | n/a | n/a | ||||||
Percentage conversion display | Yes | n/a | Yes | n/a | Yes | n/a | |||
DC voltage polarity check | n/a | n/a | Yes | n/a | |||||
Data storage | |||||||||
Capacity | Max 400 data | n/a | n/a | ||||||
USB communication*1 | Yes | Yes | n/a | ||||||
Operating time | |||||||||
Continuous operating time | Approx. 100 hours*2 | Approx. 130 hours | Approx. 40 hours | ||||||
Power supply | Alkaline (LR6) battery ×4 / Manganese(R6P) battery ×4 | Alkaline (LR03) battery ×4 | Alkaline (LR03) battery ×1 | ||||||
Display | |||||||||
Back light | Yes | Yes | Yes | ||||||
Dual display | Yes | Yes | n/a | ||||||
Bar graph display | n/a | Yes | Yes | ||||||
Safety | |||||||||
Safety standard categories | CATIII1000 V/ CATIV600 V | CATIII1000 V/ CATIV600 V | CATIII600 V/ CATIV300 V | ||||||
Mis-insertion prevention shutters | Yes | n/a | n/a |
*1. Requires optional DT4900-01 Communication Package
*2. When using four AA alkaline batteries
Multimeters Template |
|
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | Yes |
Maximum Voltage AC | 1000 V |
Maximum Voltage DC | 1000 V |
Maximum Current AC | 10 A |
Minimum Current AC | 60 uA (0.06 mA) |
Maximum Current DC | 10 A |
Minimum Current DC | 60 uA (0.06 mA) |
Basic Accuracy V DC | 0.025% |
# Digit Display | 5 |
Counts | 60000 . |
Backlight | Yes |
Manual/Autoranging | Auto-ranging |
Decibels | Yes |
Resistance | Yes |
Frequency | Yes |
Capacitance | Yes |
Temperature | Yes |
Diode Testing | Yes |
CAT Rating | IV |
CAT Voltage | 600 V |
Intrinsically Safe | No |
Peak Hold | Yes |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | Yes |
Test Equipment General Attributes |
|
Unique Features | Max/Min value display Measurement memory 400points Terminal shutter mechanism prevents erroneous lead insertion Measure larger current with optional clamps |
Interfaces I/O | USB |
Product Height | 2.09 IN |
Product Length | 7.76 IN |
Product Width | 3.66 IN |
Data Logging | Yes |
HTS/Schedule B Number | 9030.33.3400 |
ECCN Number | 3A992 |
Battery Type | AA |
Power Supply Voltage | Battery Powered |
Country of Origin | Japan |
Shipping Height | 2.75 IN |
Shipping Length | 10.00 IN |
Shipping Width | 5.00 IN |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...