Fluke 572-2 High-Temperature Infrared Thermometer
Features
Infrared Measurements | |
Temperature Range | -22 to 1652°F (-30 to 900°C) |
IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C) | ≥32°F: ±2°F or ±1% of the reading, whichever is greater ≥14°F to <32°F: ±4°F <14°F: ±6°F ≥0°C: ±1°C or ±1 % of the reading, whichever is greater ≥-10°C to <0°C: ±2°C <-10°C:±3 °C |
IR Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
Display Resolution | 0.1°F/0.1°C |
Distance:Spot | 60:1 (calculated at 90% energy) |
Minimum Spot Size | 0.75" (19 mm) |
Laser Sighting | Offset dual laser, output <1 mW |
Spectral Response | 8 µm to 14 µm |
Response Time (95%) | <500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements | |
K-Type Thermocouple Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
K-Type Thermocouple Input Accuracy | <-40°F: ±(2°F + 0.2°/1°F) ≥-40°F: ±1% or 2°F, whichever is greater <-40°C: ±(1 °C + 0.2°/1°C) ≥-40°C: ±1% or 1°C, whichever is greater |
K-Type Thermocouple | 0.1°F/0.1°C |
K-Type Thermocouple Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
Measurement Options | |
Hi/Low Alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Switchable Celsius and Fahrenheit | Yes |
Backlight | Two levels, normal and extra bright for darker environments |
Probe Input | K-type thermocouple simultaneous display of probe and IR temperature |
Trigger Lock | Yes |
Data Storage | 99 points |
Display | Dot matrix 98 x 96 pixels with function menus |
Communication | USB 2.0 |
K-Type Thermocouple Specifications | |
Measurement Range (Bead Probe) | -40 to 500°F (-40 to 260°C) |
Accuracy | ±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
Cable Length | 40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications | |
Safety and Compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Relative Humidity | 10 to 90% RH non-condensing up to 86°F (30°C) |
Operating Altitude | 2000 meters above mean sea level |
Weight | 0.7099 lb (0.322 kg) |
Power | 2 x AA batteries |
Battery Life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |