After-sales Service: | Yes |
---|---|
Warranty: | 1 Year |
Kind: | Digital Oscilloscope |
Vertical Deflection | |
Number of Channels | 4 |
Bandwidth | 200 Mhz |
Rise Time | 1.7 ns |
Channel Architecture | All inputs fully insulated from each other and from ground Inputs may be activated in any combination |
Input Coupling | AC or DC, with ground level indicator |
Input Sensitivity | With 10:1 probe, 20 mV to 1000 V/div With 100:1 probe, 200 mV to 10 kV/div Direct (1:1), 2 mV to 100 V/div |
Bandwidth Limiter | 20 MHz and 10 kHz |
Polarity | Normal, inverted, variable |
Vertical Resolution | 8 bit |
Accuracy at 4 s to 10 μs/div | 5 mV/div to 100 V/div, ±(1.5% + 6 counts) 2 mV/div, ±(1.5 % + 10 counts) |
Input impedance | 1 MΩ (±1 %) // 15 pF (±2.25 pF) |
Input Voltage Range | |
Rated Maximum Floating Voltage | CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level) |
Probe Input Voltage VPS410-II | CAT III 1000 V / CAT IV 600 V (maximum voltage between standard 10:1 probe tip and reference lead) |
Probe Input Voltage VPS421 | CAT III 1000V / CAT IV 600V (maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead) |
Maximum BNC Input Voltage | CAT IV 300 V (maximum voltage on BNC input directly) |
Memory Save and Recall | |
Memory Locations (Internal) | 30 waveform memories plus 10 recording memories plus 9 screen copy memories |
30 Waveform Memories | Each memory can contain up to 2 or 4 waveforms plus corresponding setups |
10 Recording Memories | Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements |
External Data Storage | On PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port |
Screencopies | On PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port |
Volatility | Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status |
Real-Time Clock | Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings |
Case | |
Design | Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended |
Drip and Dust Proof | IP 51 according to IEC60529 |
Shock and Vibration | Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2 |
Display Size | 5.3 x 3.5" (133 x 90 mm) LCD |
Resolution | 1120 pixels x 765 pixels |
Brightness | User-adjustable, up to 300 cd/m2 |
General Specifications | |
Temperature | Operating: Battery discharging: 32 to 104°F (0 to 40°C); battery charging: 0 to 40°C (32 to 104°F) Storage: -4 to 140°F (-20 to 60°C) |
Humidity | 32 to 50°F (0 to 10°C): noncondensing 50 to 86°F (10 to 30°C): 95% (±5%) 86 to 104°F (30 to 40°C): 75% (±5%) 104 to 122°F (40 to 50°C): 45% (±5%) |
Maximum Operating Altitude | CAT IV 600 V, CAT III 1000 V: up to 6600' (2000 m) CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 13000' (4000 m) |
Maximum Storage Altitude | 40,000' (12 km) |
Interfaces | Two USB-ports provided Ports are fully insulated from instrument's floating measurement circuitry USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2. |
Probe Calibration Output | Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel Generator Output: 1.225 Vpp / 500 Hz square wave |
Line Power | Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 VAC to 240 VAC, ±10%, 50 to 60 Hz |
Battery | Power: re-chargeable Li-Ion battery; battery swappable through easily accessible battery door at the rear of the instrument Type: BP291: 10.8V, 5000 mAh Charge indicator: battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen Operating time (with backlight low): up to 7 hours using BP291 (included) Charging time: five hours for BP291 Power saving functions: Auto 'power down' with adjustable power down time; automatic 'display off' with adjustable power down time; on-screen battery power indicator |
Dimensions | 10.5 x 7.6 x 2.8" (265 x 192 x 70 mm) |
Weight | 4.8 lbs (2.2 kg) |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...
So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.