After-sales Service: | Yes |
---|---|
Warranty: | 1 Year Warranty |
Brand Name: | Kestrel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features
5100 Racing Weather Meter
The Kestrel 5100 Pocket Weather Meter is Kestrel's Racing pit meter. Kestrel has been trusted for years for last minute tuning decisions. Get readings where it counts, on the track, not the trailer. With the new LINK technology, you can get readings right to your smartphone up to 100 feet away!
The Kestrel 5100 upgraded from the Kestrel 4250 in November of 2015. Functionally, you're getting the same environmental features with some overall big improvements to the meter itself.
Wind Speed/Air Speed | Accuracy: Larger of 3% of reading, least significant digit or 20ft/min Resolution: 0.1 m/s, 1 ft/min, 0.1 km/h, 0.1 mph, 0.1 knots, 1 B, 0.1 F/S Specification range: 0.6 to 40.0 m/s, 118 to 7,874 ft/min, 2.2 to 144.0 km/h, 1.3 to 89.5 mph, 1.2 to 77.8 knots, 0 to 12 B, 2-131.2 |
Ambient Temperature | Accuracy: 0.9°F (0.5°C) Resolution: 0.1°F (0.1°C) Specification range: -20 to 158°F (29 to 70°C) |
Relative Humidity | Accuracy: 2% RH Resolution: 0.1% RH Specification range: 10 to 90% 25°C noncondensing |
Pressure | 1.5 hPa|mbar, 0.044 inHg, 0.022 PSI Resolution: 0.1 hPa|mbar, 0.01 inHg, 0.01 PSI Specification range: 77°F (25°C), 700-1100 hPa|mbar, 20.67 to 32.48 inHg, 10.15 to 15.95 PSI |
Compass | Accuracy:5° Resolution: 1°, 1/16th Cardinal Scale Specification range: 0 to 360° |
Calculated Measurements | |
Air Density | Accuracy: 0.0002 lb/ft3 (0.0033 kg/m3) Resolution: 0.001 lb/ft3 (0.001 kg/m3) Sensors employed: Temperature, Relative, Humidity Pressure |
Air Flow | Accuracy: 6.71% Resolution: 1 cfm, 1 m3/hr, 1 m3/m, 0.1m3/s, 1 L/s Sensors employed: Air Speed,, User Input (Duct, Shape, & Size) |
Altitude | Accuracy: typical: 23.6 ft/7.2 m from 750 to 1100 mBar, max: 48.2 ft/14.7 m from 300 to 750 mBar Resolution: 1 ft/1 m Sensors employed: Pressure, User Input (Reference Pressure) |
Barometric Pressure | Accuracy: 0.07 inHg, 2.4 hPa|mbar, 0.03 PSI Resolution: 0.01 inHg, 0.1 hPa|mbar, 0.01 PSI Sensors employed: Pressure, User Input, (Reference Altitude) |