DRY-WELL, HIGH-TEMP FIELD, W/9144-INSA, 115V
Base Unit Specifications | |
Temperature Range at 23 °C | 9142 -25 °C to 150 °C (-13 °F to 302 °F) 9143 33 °C to 350 °C (91 °F to 662 °F) 9144 50 °C to 660 °C (122 °F to 1220 °F) |
Display Accuracy | 9142 ± 0.2 °C Full Range 9143 ± 0.2 °C Full Range 9144 ± 0.35 °C at 50 °C ± 0.35 °C at 420 °C ± 0.5 °C at 660 °C |
Stability | 9142 ± 0.01 °C Full Range 9143 ± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C 9144 ± 0.03 °C at 50 °C ± 0.04 °C at 420 °C ± 0.05 °C at 660 °C |
Axial Uniformity at 40 mm (1.6 in) | 9142 ± 0.05 °C Full Range 9143 ± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C 9144 ± 0.05 °C at 50 °C ± 0.35 °C at 420 °C ± 0.5 °C at 660 °C |
Radial Uniformity | 9142 ± 0.01 °C Full Range 9143 ± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C 9144 ± 0.02 °C at 50 °C ± 0.05 °C at 420 °C ± 0.10 °C at 660 °C |
Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes) | 9142 ± 0.006 °C Full Range 9143 ± 0.015 °C Full Range 9144 ± 0.015 °C at 50 °C ± 0.025 °C at 420 °C ± 0.035 °C at 660 °C |
Hysteresis | 9142 0.025 9143 0.03 9144 0.1 |
Operating Conditions | 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) |
Environmental Conditions (for all specifications except temperature range) | ± 1.0 % RH for ± 5 % changes within 20 % RH to 70 % RH |
RH Resolution | 13 °C to 33 °C |
Immersion (Well) Depth | 150 mm (5.9 in) |
Insert OD | 9142 30 mm (1.18 in) 9143 25.3 mm (1.00 in) 9144 24.4 mm (0.96 in) |
Heating Time | 9142 16 min: 23 °C to 140 °C 23 min: 23 °C to 150 °C 25 min: -25 °C to 150 °C 9143 5 min: 33 °C to 350 °C 9144 15 min: 50 °C to 660 °C |
Cooling Time | 9142 15 min: 23 °C to -25 °C 25 min: 150 °C to -23 °C 9143 32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C 9144 35 min: 660 °C to 50 °C 25 min: 660 °C to 100 °C |
Resolution | 0.01 ° |
Display | LCD, °C or °F user-selectable |
Size (H x W x D) | 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) |
Weight | 9142 8.16 kg (18 lb) 9143 7.3 kg (16 lb) 9144 7.7 kg (17 lb) |
Power Requirements | 9142 100 V to 115 V (± 10 %) 50/60 Hz, 635 W 230 V (± 10 %) 50/60 Hz, 575 W 9143100 V to 115 V (± 10 %), 50/60 Hz, 1400 W 230 V (± 10 9144 %), 50/60 Hz, 1800 W |
Computer Interface | RS-232 and 9930 Interface-it control software included |
-P Specifications | |
Built-in Reference Thermometer Readout Accuracy (4-Wire Reference Probe)† | ± 0.010 °C at -25 °C ± 0.015 °C at 0 °C ± 0.020 °C at 50 °C ± 0.025 °C at 150 °C ± 0.030 °C at 200 °C ± 0.040 °C at 350 °C ± 0.050 °C at 420 °C ± 0.070 °C at 660 °C |
Reference Resistance Range | 0 ohms to 400 ohms |
Reference Resistance Accuracy‡ | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading |
Reference Characterizations | ITS-90, CVD, IEC-751, Resistance |
Reference Measurement Capability | 4-wire |
Built-in RTD Thermometer Readout Accuracy | NI-120: ± 0.015 °C at 0 °C PT-100 (385): ± 0.02 °C at 0 °C PT-100 (3926): ± 0.02 °C at 0 °C PT-100 (JIS): ± 0.02 °C at 0 °C |
RTD Resistance Range | 0 ohms to 400 ohms |
RTD Resistance Accuracy‡ | 0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading |
RTD Characterizations | PT-100 (385),(JIS),(3926), NI-120, Resistance |
RTD Measurement Capability | 4-wire RTD (2-,3-wire RTD w\ Jumpers only) |
RTD Connection | 4 terminal input |
Built-in TC Thermometer Readout Accuracy | Type J: ± 0.7 °C at 660 °C Type K: ± 0.8 °C at 660 °C Type T: ± 0.8 °C at 400 °C Type E: ± 0.7 °C at 660 °C Type R: ± 1.4 °C at 660 °C Type S: ± 1.5 °C at 660 °C Type M: ± 1.4 °C at 660 °C Type L: ± 0.7 °C at 660 °C Type U: ± 0.75 °C at 600 °C Type N: ± 0.9 °C at 660 °C Type C: ± 1.1 °C at 660 °C |
TC Millivolt Range | -10 mV to 75 mV |
Voltage Accuracy | 0.025% of reading + 0.01 mV |
Internal Cold Junction Compensation Accuracy | ± 0.35 °C (ambient of 13 °C to 33 °C) |
TC Connection | Small connectors |
Built-in mA Readout Accuracy | 0.02 % of reading + 2 mV |
mA Range | Cal 4-22 mA, Spec 4-24 mA |
mA Connection | 2 terminal input |
Loop Power Function | 24 V DC loop power |
Built-in Electronics Temperature Coefficient (0 °C to 13 °C, 33 °C to 50 °C) | ± 0.005 % of range per °C |
† The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.C ‡ Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. X in the above model numbers to be replaced with A, B, C, D, E, or F as appropriate for the desired insert. See the inserts illustration and listing below. |
Calibration Baths | |
---|---|
Type | Dry |
Min Temp (Calibration Baths) | 50 C |
Max Temp (Calibration Baths) | 660 C |
Accuracy (Calibration Baths) | 0.35 C |
Voltage (Calibration Baths) | 115 / 220 VAC, 115 VAC, 220 VAC |
Special Features (Calibration Baths) | Inserts Available (Dry Baths), PC Software, Programmable Tests |
Test Equipment General Attributes | |
Interfaces I/O | RS-232 |
Product Height | 12.75 IN |
Product Length | 19.75 IN |
Product Width | 16.25 IN |
ECCN Number | EAR99 |
Calibration Included | NIST Calibration |
Country of Origin | United States |
Shipping Height | 12.75 IN |
Shipping Length | 19.75 IN |
Shipping Width | 16.25 IN |