Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester

Product Details
After-sales Service: Yes
Warranty: 1 Year Warranty
Display Type: Digital Only
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (7)
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
  • Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
Find Similar Products
  • Overview
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Megger MIT1025
Certification
RoHS, CE
Customized
Non-Customized
Brand Name
Megger
Model
Mit1025
Insulation Range, Analog
100kw to 10tw
Insulation Range, Digital
10kw to 20tw
Test Voltages
500V, 1000V, 2500V, 5000V, and 10,000V
Frequency Range
45 to 65Hz
Insulation Alarm
100KΩ to 1gΩ
Current Range
0.01na to 6mA
Transport Package
DHL/UPS/FedEx
Specification
50*37*34cm
Trademark
megger
Origin
U. K.
HS Code
9030331000
Production Capacity
50, 000 Pieces/Year

Product Description

Analog/Digital 10kV Megger; 500, 1000, 2500, 5000, 10,000V; 20 Tohms; Cat IV 600V.

MIT1025 Insulation Tester 10kV IRT, IR, IR(t), DAR, PI, DD, SV, Ramp, USB, Battery and line powered to 20TOhms

  • Output voltage maximum 10kV
  • Resistance range max 20TΩ
  • Accuracy ±5% ≤ 2TΩ/±20%to20TΩ
  • Smaller size and lighter weight
  • High measurement range
  • Unique dual case design
  • High-quality, flexible silicon test leads meet safety regulations of IEC 61010-31:2008 while ensuring measurement accuracy.
  • Timed IR plus PI, DAR, DD, SV and ramp tests maximize diagnostic testing capability.
  • Operate from line power when battery fully discharged (charges while operating).
    Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester

    Megger MIT1025 - 10 kV Diagnostic Insulation Resistance Tester

    What's included with the Megger MIT1025

    MIT1025 Megohmmeter
    Power lead
    3 x 1002-531 Medium insulated clips, 10ft (3m) leadset
    3 x 1002-534 Large insulated clips, 10ft (3m) leadset
    User guide CD
    The MIT1025 insulation resistance tester from Megger includes numerous special and unique features as well as powerful standard specifications, making the unit well-suited to diagnostic testing work in high voltage applications at a professional level. The MIT1025 is a 10 kV unit with available output voltages of 500 V, 1000 V, 2500 V, 5000 V, and 10000 V. The unit also features a user-defined lock voltage function, meaning any selectable test voltage may be locked and restored via the selector switch.
The MIT1025 is capable of performing resistance measurements from 10 kΩ up to 20 TΩ. Accuracy is ±5% from 1MΩ to 2 TΩ when testing at 10 kV. The MIT1025 also features up to 6mA noise immunity as well as 3mA short circuit current. The unit also includes a built-in dedicated voltmeter with an operating range of 30 V to 660 V.
Product Parameters
Insulation Range, Analog 100kW to 10TW
Insulation Range, Digital 10kW to 20TW
Test Voltages 500V, 1000V, 2500V, 5000V, and 10,000V
User Defined Test Voltages 100V to 1kV in 10V steps
1kV to 5kV in 25V steps
5kV to 10kV in 25V steps
Accuracy ±5% to 2TΩ, ±20% to 20TΩ
Voltage Output Accuracy +4% -0% ±10V of nominal test voltage at 1GW load
Voltmeter Range 30 to 660V AC/DC, 50/60Hz
Voltmeter Accuracy ±3% ±3V
Frequency Range 45 to 65Hz
Short Circuit Current 3mA nominal, max. power on all loads outperforming many 5mA testers
Insulation Alarm 100kΩ to 1GΩ
Current Range 0.01nA to 6mA
Current Accuracy ±5% ±0.2 nA at all voltages
Capacitance Range (above 500V) 10nF to 25µF (dependent on measurement voltage)
Capacitance Accuracy ±10% ±5nF
Capacitor Charge <5s per µF at 3mA to 10kV
Capacitor Discharge <500 ms/µF to discharge from 10,000V to 50V
   
Packaging & Shipping

 

Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
 
Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester
Megger Mit1025 10 Kv Diagnostic Insulation Resistance Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier