Insulation test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
Resolution | 0.1 kΩ |
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) |
Open circuit voltage | -0% +2% ± 2V |
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. |
Leakage | 10% ±3 digits |
Voltage | 3% ±3 digits ±0.5% of rated voltage |
Timer control | 60 second countdown timer |
Guard terminal performance | <5% error at 500 kΩ |
Continuity measurement | 0.01 Ω to 999 kΩ (0 to 1000 kΩ on analog scale) |
Open circuit voltage | 5 V ± 1 V |
Test Current | 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω) |
Polarity | Single polarity (Default) / Dual polarity (configurable on setup). |
Lead resistance | Null up to 9.00 Ω |
Voltage range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V |
Frequency measurement range | 15 Hz - 400 Hz |
Frequency measurement | ±0.5% ± 1digit (100 Hz to 400 Hz) |
Capacitance measurement | 100 pF to 10 μF |
Storage capacity | >1000 test results |
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ Charger (Optional): 12-15 V dc (accessory interface) |
Temperature co-efficient | < 0,1% per °C up to 1 GΩ, < 0,1% per °C per GΩ above 1 GΩ |
Dimensions | Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) |
Weight | 600 g (MIT400/2), (28.74 oz) |