After-sales Service: | Yes |
---|---|
Warranty: | 1year |
Certification: | CE, ISO |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
With the AT-6010 Advanced Wire Tracer, it's never been easier and safer to locate Energized and De-energized wires, breakers and fuses. When the Transmitter is connected to the circuit, the Receiver easily detects the signal in the wires or cables behind walls, ceilings and floors.
The Transmitter works on Energized and De-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The Transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.
The complete AT-6010 kit features test leads and accessories International accessory kit for use outside North America.
AT6000 Series Specifications | |||
Features | AT-6010-R Receiver | AT-6010-T Transmitter | CT-400 Signal Clamp |
Measurement category | CAT III 600 V | CAT III 600 V | CAT IV 600 V, CAT III 1000 V |
Operating voltage | 0 to 600 V AC/DC | 0 to 600 V AC/DC | 0 to 1000 V AC |
Operating frequency | Energized: 6.25 kHz, De-Energized: 32.768 kHz | Energized: 6.25 kHz, De-Energized: 32.768 kHz | AC current measurement: 45 Hz to 400 Hz |
Hazardous voltage detection | - | > 30 V AC/DC | - |
Signal indications | Numeric, bar graph display and audible beep | LEDs | - |
Response time | Tip Sensor (Energized/De-energized): 500 ms Battery voltage monitoring: 5 sec |
Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
Instantaneous |
Current output of signal (typical) | - | Energized circuit: HI mode: 60 mA RMS De-energized circuit: HI mode: 130 mA RMS Loop mode: 160 mA RMS |
1 mA/A for AC current measurement with multimeter |
Signal voltage output (nominal) | - | De-energized circuit: HIGH: 33V RMS, 140 Vp-p With CT-400: loop mode: 31 V RMS, 120 Vp-p |
De-energized circuit: 2.4 V RMS, 24 Vp-p |
Range detection (open air | Tip sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm |
- | - |
General Specifications | |||
Display size | LCD 2.5 in (6.35 cm) | - | - |
Display dimensions (W x H) | 1.45 x 1.93 in (36.72 x 48.96 mm) | - | - |
Display type | Segment LCD | LEDs | - |
Display color | Black and white | Operating mode LEDs: red, Battery status LEDs: red | - |
Booting time | < 3 sec | < 2 sec | - |
Backlight | • | - | - |
Operating temperature | 4 °F to 122 °F (-20 °C to 50 °C) | 32 °F to 122 °F (0 °C to 50 °C) | |
Operating humidity | 45%: -4 °F to <50 °F (-20 °C to <10 °C), 95%: 50 °F to <86 °F (10 °C to <30 °C) 75%: 86 °F to <104 °F (30 °C to <40 °C), 45%: 104 °F to 122 °F (40 °C to 50 °C) |
95%: 50 °F to <86 °F (10 °C to <30 °C) 75%: 86 °F to <104 °F (30 °C to <40 °C) 45%: 104 °F to <122 °F (40 °C to <50 °C) |
|
Storage temperature and humidity | -4 °F to 158 °F (-20 °C to 70 °C), <95% RH | -4 °F to 158 °F (-20 °C to 70 °C), <95% RH | |
Operating altitude | 0 to 6561 ft (2000 m) | 0 to 6561 ft (2000 m) | |
Transient protection | - | 6.00 kV (1.2/50μS surge) | - |
Pollution degree | 2 | 2 | 2 |
IP rating | IP 52 | IP 40 | IP 40 |
Drop test | 3.28 ft (1 m) | 3.28 ft (1 m) | 3.28 ft (1 m) |
Power supply | 4 x AA (alkaline) | 8 x AA (alkaline) | - |
Power consumption (typical) | 70 mA | Hi mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
- |
Battery life | Approx. 25 h | Hi mode: approx. 25 h Loop mode: approx. 18 h |
- |
Low battery indication | • | • | - |
Fuse | - | - | 1.26 in (32 mm) |
Dimensions (L x W x H) | Approx. 7.2 x 2.95 x 1.69 in (183 x 75 x 43 mm) | Approx. 7.2 x 3.66 x 1.97 in (183 x 93 x 50 mm) | Approx. 5.9 x 2.75 x 1.18 in (150 x 70 x 30 mm) |
Weight | Approx. 0.6 lb (0.27 kg) | Approx. 1.25 lb (0.57 kg) | Approx. 0.25 lb (0.114 kg) |
Wire Tracers / Circuit Breaker Tracers/Wire Tracers / Circuit Breaker Tracers Template |
|
---|---|
Tests | Shorts |
Energized Circuits | Yes |
De-energized Circuits | Yes |
Maximum Circuit Distance | 20 Ft |
Underground/Hidden Cable Capability | Yes |
Type of Alarm | Audible, Visual |
Tone Generator | Yes |
Clamp-on Attachment | No |
Identifies Breakers | Yes |
Distance to Wire | No |
Test Equipment General Attributes |
|
Warranty | 1 YEARS |
Safety Approval | CSA, UL |
Product Weight | 2.1 LBS |
Product Height | 9.45 IN |
Product Length | 13.00 IN |
Product Width | 9.45 IN |
Data Logging | No |
ECCN Number | 3A992 |
Battery Type | AA |
Country of Origin | China |