This product is no longer promoted on Made-in-China.com. If you find any infringement or sensitive information of it, please contact us for handling. Thank you.

Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz

Product Details
After-sales Service: Yes
Warranty: 1 Year
Kind: Digital Oscilloscope
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
  • Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Find Similar Products

Basic Info.

Model NO.
Fluke 125B
Channel Number
2
Structure
Desktop
Application
Voltage Measurement, Magnetic Field Measurement, Pressure Measurement, Displacement Measurement, Temperature Measurement, Impedance Measurement, Electric Power Measurement, Phase Measurements, Time Measurement, Frequency Measurement
Sampling Mode
Real-time Sampling
Bandwidth
20 MHz
Trigger Modes
Automatic
Sampling Rate
400 K Sample/S
Built-in Signal Source
With Built-in Signal Source
Transport Package
UPS/DHL/FedEx
Specification
259 x 132 x 55MM
Trademark
FLUKE
Origin
USA
HS Code
9030201000
Production Capacity
50, 000 Pieces/Year

Product Description

Product Parameters
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz

 

  • Fluke 125B/NA 40 MHz, 2-Channel, 40 MS/s Industrial ScopeMeter Hand-Held Oscilloscope with Bus Health and Fluke Connect Compatibility

    • 125B/NA Industrial ScopeMeter Handheld Oscilloscope with Bus Health Test 40MHz (North America)
    • Dual-input digital oscilloscope and multimeter
    • 40 MHz or 20 MHz oscilloscope bandwidth
    • Two 5,000-count true-rms digital multimeters
    • Connect-and-View™ trigger simplicity for hands-off operation
    • IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
    • Dual-input waveform and meter reading recorder for trending data over extended periods
    • Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
    • Shielded test leads for oscilloscope, resistance and continuity measurements
    • Resistance, continuity, diode and capacitance meter

Description

Fluke 125B/NA - Industrial ScopeMeter Handheld Oscilloscope with Bus Health Test 40MHz (North America)

 
  • 40 MHz or 20 MHz Oscilloscope Bandwidth
  • Shielded test leads for oscilloscope, resistance and continuity measurements
  • Resistance, continuity, diode and capacitance meter measurements
  • Power measurements (W, VA, VAR, PF, DPF, Hz)

Simplified testing, more insight and faster electro-mechanical troubleshooting

 

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

The 120B Series Industrial ScopeMeter test tools include innovative functions designed to help technicians troubleshoot faster and get the answers they need to keep their systems up and running. Display waveforms with Connect-and-View™ trigger and setup technology and automatically view related numerical measurements using Fluke IntellaSet™ technology, all without making manual measurement adjustments. With Recorder Event Detect capabilities, elusive intermittent events are captured and logged for easy viewing and analysis.

Connect-and-View™ triggering for an instant, stable display

 

Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. Fluke's unique Connect-and-View™ triggering technology recognizes signal patterns, and automatically sets up the correct triggering to provide a stable, reliable and repeatable display. Connect-and-View™ triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.

Harmonics measurements

 

Harmonics are periodic distortions of voltage, current, or power sine waves. Harmonics in power distribution systems are often caused by non-linear loads such as switched mode dc power supplies and adjustable speed motor drives. Harmonics can cause transformers, conductors, and motors to overheat. In the Harmonics function, the Test Tool measures harmonics to the 51st. Related data such as dc components, THD (Total Harmonic Distortion), and K factor are measured to provide a complete insight in to the electrical state of health of your loads.

In The Box

  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • USB Angled Adapter
  • WiFi USB Adapter (not for use in all countries)
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack

Manuals/Guides

Manuals
  • Fluke 123B/124B/125B Industrial ScopeMeter User Manual
  • Fluke 123B/124B/125B Industrial ScopeMeter Supplement Users Manual
  • Fluke 123B/124B/125B Industrial ScopeMeter Calibration Manual
Spec Sheets
  • Fluke 120B Series Industrial ScopeMeter Hand-Held Oscilloscopes Data Sheet
  • Fluke Material Safety Data Sheet
Application Notes
  • Five Reasons to Upgrade your Hand-held Oscilloscope Application Note
  • Making Sense of Electrical Signals Application Note
  • Verifying Hydraulic Control System Operation with Fluke ScopeMeter 120 Series Test Tools
  • How good data helps manage PV and microgrid performance - Application Note
Other
  • Fluke 123B/124B/125B Industrial ScopeMeter Safety Sheet
  • Statement of Memory Volatility
  • Fluke Solar Industry Solutions

Manufacturer Specs

Fluke 120B Series Specifications
Oscilloscope mode
Vertical
Frequency response - dc
coupled
Without probes and test leads
(with BB120)
123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3
dB)
With STL120-IV 1:1 shielded test
leads
DC to 12.5 MHz (-3 dB) / dc to 20
MHz (-6 dB)
With VP41 10:1 Probe123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3
dB)
Frequency response - ac
coupled (lf roll off)
Without probes and test leads<10 Hz (-3 dB)
With STL120-IV 1:1 shielded test
leads
<10 Hz (-3 dB)
With VP41 10:1 Probe<10 Hz (-3 dB)
Rise time, excluding probes,
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedanceWithout probes and test
leads
1 MΩ//20 pF
With BB1201 MΩ//24 pF
With STL120-IV 1:1 shielded test
leads
1 MΩ//230 pF
With VP41 10:1 Probe5 MΩ//15.5 pF
Sensitivity5 mV to 200 V/div
Analog bandwidth limiter10 kHz
Display modesA, -A, B, -B
Max. input voltage A and BDirect, with test leads, or with
VP41 Probe
600 Vrms Cat IV, 750 Vrms
maximum voltage.
With BB120600 Vrms
Max. floating voltage, from any
terminal to ground
600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modesNormal, Single, Roll
Ranges (normal)Equivalent sampling123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500
ns/div
Real time sampling1 µs to 5 s/div
Single (real time)1 µs to 5 s/div
Roll (real time)1s to 60 s/div
Sampling rate (for both
channels simultaneously)
Equivalent sampling (repetitive
signals)
Up to 4 GS/s
Real time sampling 1 µs to 60
s/div
40 MS/s
Trigger
Screen updateFree run, on trigger
SourceA, B
Sensitivity A and B@ DC to 5 MHz0.5 divisions or 5 mV
@ 40 MHz123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz123B: N/A
124B and 125B: 4 divisions
SlopePositive, negative
Advanced scope functions
Display modesNormalCaptures up to 25 ns glitches and
displays analog-like persistence
waveform
SmoothSuppresses noise from a waveform
Glitch offDoes not capture glitches between
samples
EnvelopeRecords and displays the minimum
and maximum of waveforms over
time
Auto set (Connect-and-View™)Continuous fully automatic adjustments of amplitude, time base, trigger
evels, trigger gap, and hold-off. Manual override by user adjustment of
amplitude, time base, or trigger level.
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1
probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen.
Input A and input B
DC voltage (VDC)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy±(0.5% +5 counts)
Common mode rejection
(CMRR)
>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range
(DC coupled)
DC to 60 Hz (V ac+dc)±(1% +10 counts)
1 Hz to 60 Hz (V ac)±(1% +10 counts)
Accuracy for 5% to 100% of range
(AC or dc coupled)
60 Hz to 20 kHz±(2.5% +15 counts)
DC rejection (only VAC)>50 dB
Common mode rejection
(CMRR)
>100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts, reading is independent of any signal crest factor.
Peak
ModesMax peak, Min peak, or pk-to-pk
Ranges500 mV, 5 V, 50 V, 500 V, 2200 V
AccuracyAccuracy Max peak or Min peak5% of full scale
Accuracy Peak-to-Peak10% of full scale
Full scale reading500 counts
Frequency (Hz)
Ranges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz,
and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz,
10 MHz, and 70 MHz
Frequency range15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz±(0.5% +2 counts)
Full scale reading10,000 counts
RPM
Max reading50.00 kRPM
Accuracy±(0.5% +2 counts)
Duty cycle (PULSE)
Range2% to 98%
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading1000 counts
Amperes (AMP)
With current clampRangesSame as V dc, V ac, V ac+dc, or
PEAK
Scale factors0.1 mV/A, 1 mV/A, 10 mV/A, 100
mV/A, 400 mV/A, 1 V/A, 10
mV/mA
AccuracySame as V dc, V ac, V ac+dc, or
PEAK (add current clamp
uncertainty)
Temperature (TEMP) with optional temperature probe
Range200 °C/div (200 °F/div)
Scale factor1 mV/°C and 1 mV/°F
AccuracyAs V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV1 V
0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 Ω
dB onV dc, V ac, or Vac+dc
Full scale reading1000 counts
Crest factor (CREST)
Range1 to 10
Full scale reading90 Counts
Phase
ModesA to B, B to A
Range0 to 359 degrees
Resolution1 degree
Power (125B only)
Configurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental
component only, AUTOSET mode only)
Power factor (PF)Ratio between watts and VA range - 0.00 to 1.00
WattRMS reading of multiplying corresponding samples of input A (volts)
and input B (amperes)
Full scale reading999 counts
VAVrms x Arms
Full scale reading999 counts
VA reactive (var)v((VA)2-W2)
Full scale reading999 counts
Vpwm
PurposeTo measure on pulse width modulated signals, like motor drive inverter
outputs
PrincipleReadings show the effective voltage based on the average value of
samples over a whole number of periods of the fundamental frequency
AccuracyAs Vrms for sinewave signals
Input A to common
Ohm (Ω)
Ranges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading50 O to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage<4 V
Continuity (Cont)
Beep<(30 O ±5 Ω ) in 50 Ω range
Measurement current0.5 mA
Detection of shorts of=1 ms
Diode
Measurement voltage@0.5 mA>2.8 V
@open circuit<4 V
Measurement current0.5 mA
Polarity+ on input A, - on COM
Capacitance (CAP)
Ranges50 nF, 500 nF, 5 µF, 50 µF, 500 µF
Full scale reading5000 counts
Measurement current500 nA to 0.5 mA, increases with increasing ranges
Advanced meter functions
Zero SetSet actual value to reference
AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable.
AutoHold works on the main meter reading, with thresholds of 1 Vpp
for AC signals and 100 mV for DC signals.
Fixed decimal pointActivated by using attenuation keys
Cursor Readout (124B and 125B)
SourcesA, B
Single vertical lineAverage, min and max readout
Average, min, max and time from start of readout (in ROLL mode;
instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode;
instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical linesPeak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal linesHigh, low and peak-peak readout
Rise or fall timeTransition time, 0%-level and 100%-level readout (manual or auto
leveling; auto leveling only
possible in single channel mode)
AccuracyAs oscilloscope accuracy
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples
in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the
125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter
measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement SpeedMaximum 2 measurement/s
Record Size (min, max, average)2 M readings for 1 channel
Recorded Time Span2 weeks
Maximum number of events1024
Waveform record
Maximum sample rate400 K sample/s
Size Internal memory400 M samples Recorded Time
Span internal memory15 minutes at 500 µs/div
11 hours at 20 ms/div
Record Size SD card1.5 G samples
Recorded Time Span SD card11 hours at 500 µs/div
14 days at 20 ms/div
Maximum number of events64
Power Quality (125B only)
ReadingsWatt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto)250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r)±(2% + 6 counts)
When selected: fundamental (% f)±(4% + 4 counts)
DPF0.00 to 1.00
PF0.00 to 1.00, ±0.04
Frequency range10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of HarmonicsDC to 51
Readings / Cursor readings
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /WattEach harmonic from fundamental
maybe selected for individual
readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
BusHealth tester (Fluke 125B only)
TypeSubtypeProtocol
AS-iNEN-EN50295
CANISO-11898
Interbus SRS-422EIA-422
ModbusRS-232RS-232/EIA-232
RS-485RS-485/EIA-485
Foundation FieldbusH161158 type 1, 31.25 kBit
ProfibusDPEIA-485
PA61158 type 1
Miscellaneous
DisplayType5.7-inch color active matrix TFT
Resolution640 x 480 pixels
Waveform DisplayVertical10 div of 40 pixels
Horizontal12 div of 40 pixels
PowerExternalVia Power Adapter BC430
Input voltage10 V DC to 21 V DC
Power consumption5 W typical
Input connector5 mm jack
InternalVia Battery Pack BP290
Battery powerRechargeable Li-Ion 10.8 V
Operating time7 hours with 50% backlight brightness
Charging time4 hours with test tool off, 7 hours with test tool on
Allowable ambient temp0 to 40 °C (32 to 104 °F) during charging
MemoryInternal memory can store
20 data sets (screen
waveform and setup)
Micro SD card slot with optional SD card (max size of 32 GB)
MechanicalSize259 x 132 x 55 mm
(10.2 x 5.2 x 2.15 in)
Weight1.4 kg (3.2 lb) including battery pack
InterfaceOptically isolatedTransfer screen copies (bitmaps), settings and data
USB to PC/laptopOC4USB optically isolated USB adapter/cable, (optional), using
FlukeView® software for Windows®.
Optional WiFi adapterFast transfer of screen copies (bitmaps), settings and data to
PC/laptop, tablet, smartphone, etc. A USB port is provided for
attaching the WiFi dongle. Do not use the USB port with a cable
for safety reasons.
Environmental
EnvironmentalMIL-PRF-28800F, Class 2
TemperatureBattery Operation0 to 40 °C (32 to 104 °F)
Power Adapter Operation0 to 50 °C (32 to 122 °F)
Storage-20 to 60 °C (-4 to 140 °F)
Humidity (Operating)@ 0 to 10 °C (32 to 50 °F)Non-condensing
@ 10 to 30 °C (50 to 86 °F)95%
@ 30 to 40 °C (86 to 104 °F)75%
@ 40 to 50 °C (104 to 122 °F)45%
Storage@ -20 to 60 °C (-4 to 140 °F)Non-condensing
AltitudeOperating at 3 km (10,000 feet)CAT III 600 V
Operating at 2 km (6,600 feet)CAT IV 600 V
Storage12 km (40,000 feet)
EMC electromagnetic
compatibility
InternationalIEC 61326-1: Industrial, CISPR 11: Group 1,
Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting &
Communication Equipment)
USA (FCC)47 CFR 15 subpart B. This product is
considered an exempt device per clause
15.103.
Wireless radio with
adapter
Frequency range2412 MHz to 2462 MHz
Output power<100 mW
Enclosure protectionIP51, ref: EN/IEC60529
SafetyGeneralIEC 61010-1: Pollution Degree 2
MeasurementIEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input
A and B
Direct on input or with leads600 Vrms CAT IV for derating
With Banana-to-BNC Adapter
BB120
600 Vrms for derating
Max. floating voltage from
any terminal to ground
600 Vrms Cat IV, 750 Vrms up to 400 Hz

Tech Specs

Multimeters Template

StyleHand-Held
Measures AC VYes
Measures DC VYes
Measures AC ANo 
Measures DC ANo 
True RMSYes
Maximum Voltage AC750 V
Maximum Voltage DC750 V
Basic Accuracy V DC±(0.5 % + 5 counts)
Counts5000 .
BacklightYes
Manual/AutorangingBoth
DecibelsYes
ResistanceYes 
FrequencyYes 
CapacitanceYes 
TemperatureNo 
Diode TestingYes
CAT RatingIV 
CAT Voltage600 V
Intrinsically SafeNo
Peak HoldNo 
Overload ProtectorNo
Kelvin 4-Wire Measurement CapabilityNo
Wireless DisplayNo
Data HoldNo
Low-Pass FilterNo
Duty Cycle %2% to 98%

Oscilloscopes/Portable Oscilloscopes Template

Bandwidth40 MHz
Channels2
Sampling Rate40 MS/S 
Screen Type (Oscilloscopes)TFT/LCD
Isolated InputsNo
Screen Size5.7 IN
Color ScreenYes
Rise Time8.75 ns
Memory400 MP [megapoints] (409600 kB)

Test Equipment General Attributes

Unique FeaturesPower measurements (W, VA, VAR, PF, DPF, Hz)
Dual-input digital oscilloscope and multimeter.
Warranty3 YEARS
Safety ApprovalCE, CSA
Interfaces I/OUSB 
StorageInternal Memory, Micro SD
IP RatingIP51
Product Weight1.4 KILOS (3.09 LBS)
Product Height2.15 IN
Product Length10.2 IN
Product Width5.2 IN
Data LoggingYes
Calibration IncludedNone
Battery TypeLi-ion
Power Supply VoltageBattery Powered
Country of OriginRomania
Shipping Height5.75 IN
Shipping Length14.00 IN
Shipping Width12.25 IN

 

 

 

 
Packaging & Shipping

 

Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz
Fluke 125b Industrial Scopemeter Hand-Held Oscilloscope with AC Clamp, 40 MHz

As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...    


So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.

 

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now